Ultrasound speckle statistics variations with imaging system impulse response

Show simple item record

dc.contributor.author Rao, Navalgund en_US
dc.contributor.author Mehra, Sumat en_US
dc.contributor.author Zhu, Hui en_US
dc.date.accessioned 2006-12-18T18:26:49Z en_US
dc.date.available 2006-12-18T18:26:49Z en_US
dc.date.issued 1990-12-04 en_US
dc.identifier.citation Proceedings of the IEEE Ultrasonics Symposium 3 (1990) 1435-1440 en_US
dc.identifier.issn 1051-0117 en_US
dc.identifier.uri http://hdl.handle.net/1850/3221 en_US
dc.description "Ultrasound speckle statistics variations with imaging system impulse response," Proceedings of the 1990 IEEE Ultrasonics Symposium. Institute of Electrical and Electronics Engineers. Held in Honolulu, Hawaii: 4-7 December 1990. ©1990 Institute of Electrical and Electronics Engineers (IEEE). Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE. This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder. en_US
dc.description.abstract The statistics of speckle depends on the density of scatterers and the resolution cell volume. The resolution cell volume depends on the impulse response of the imaging system. A fully developed speckle results from interference of scattered waves from a high density of random scatterers within a resolution cell volume. In such cases, the envelope detected signal is known to possess a Rayleigh distribution and a signal to noise ratio (SNR) of 1.91 whereas the intensity signal has a limiting SNR value of 1. Previous publications have shown that SNR can drop below this value when scatterer density departs from high density limit. It has been suggested that SNR be used as a tissue characterization parameter. In this paper, we show that a similar behavior can be observed when resolution cell volume is varied for a fixed scatterer density, and demonstrate it's usefulness in tissue characterization. A three dimensional (3D) simulation phantom that takes into account 3D distribution of scatterers and the 3D nature of resolution cell volume, has been used. The medium is modeled as a uniform matrix material with discrete scatterers distributed randomly. Envelope detection from the simulated RF signal is carried out using Hibert transform. Several simulations were performed to study the effect of scatterer number density (n) and the resolution cell volume on the SNR. We report results with several major implications: (i) It is the number of scatterers within a resolution cell volume that determine the high density limiting behavior. We find this number to be around 10 for a full width at half maximum analysis of the resolution cell volume. (ii) A plot of SNR vs. resolution cell volume of the imaging system for various scatterer number densities reveals the sensitivity of different systems for tissue characterization. (iii) If we have the information about the system's resolution cell volume, then the scatterer number density can be estimated from the SNR measurements. (iv) Higher order moments can be more useful in number density estimation. But our analysis shows that higher moments are even more sensitive to variations in resolution cell volume. en_US
dc.description.sponsorship This work was supported in part by a grant-in-aid #881095 awarded by the American Heart Association and by a DuPont science and engineering grant. en_US
dc.format.extent 517911 bytes en_US
dc.format.mimetype application/pdf en_US
dc.language.iso en_US en_US
dc.publisher The Institute of Electrical and Electronics Engineers (IEEE) en_US
dc.relation.ispartofseries vol. 3 en_US
dc.subject Acoustic imaging en_US
dc.subject Biomedical ultrasonics en_US
dc.subject Speckle en_US
dc.title Ultrasound speckle statistics variations with imaging system impulse response en_US
dc.type Proceedings en_US