The Verification of an optical system design for a low frequency MTF camera

Show full item record

Title: The Verification of an optical system design for a low frequency MTF camera
Author: Hoel, Edwin B.
Abstract: A proposed low frequency MTF camera system uses a cylinder lens to smear an area-modulated sinusoidal target into an irradiance-modulated sinusoidal image for the evaluation of a film's modulation transfer characteristics. The proposed system was constructed and evaluated. Resolution limits, field flatness, field sharpness, repeatability, de focus effects and system MTF were determined. The camera was tested with film and found to have an MTF value close to 1.0 for frequencies up to 10 cycles/mm at which point the function dropped off to a value of 0.2 at 30 cycles/mm. Off-axis images showed rapid degredation as a maximum MTF value of 0.05 for 30 cycles/mm was exhibited at the edges of the image field.
Record URI: http://hdl.handle.net/1850/8358
Date: 1980-05

Files in this item

Files Size Format View
EHoelThesis05-1980.pdf 945.2Kb PDF View/Open

The following license files are associated with this item:

This item appears in the following Collection(s)

Show full item record