The Verification of an optical system design for a low frequency MTF camera

Show simple item record

dc.contributor.advisor Unknown
dc.contributor.author Hoel, Edwin B.
dc.date.accessioned 2009-02-19T16:57:45Z
dc.date.available 2009-02-19T16:57:45Z
dc.date.issued 1980-05
dc.identifier.uri http://hdl.handle.net/1850/8358
dc.description.abstract A proposed low frequency MTF camera system uses a cylinder lens to smear an area-modulated sinusoidal target into an irradiance-modulated sinusoidal image for the evaluation of a film's modulation transfer characteristics. The proposed system was constructed and evaluated. Resolution limits, field flatness, field sharpness, repeatability, de focus effects and system MTF were determined. The camera was tested with film and found to have an MTF value close to 1.0 for frequencies up to 10 cycles/mm at which point the function dropped off to a value of 0.2 at 30 cycles/mm. Off-axis images showed rapid degredation as a maximum MTF value of 0.05 for 30 cycles/mm was exhibited at the edges of the image field. en_US
dc.language.iso en_US en_US
dc.subject Photographic optics en_US
dc.subject Cameras en_US
dc.subject Optical system en_US
dc.title The Verification of an optical system design for a low frequency MTF camera en_US
dc.type Thesis en_US
dc.description.college College of Graphic Arts and Photography en_US
dc.description.department School of Photographic Arts and Sciences en_US
dc.contributor.advisorChair Unknown

Files in this item

Files Size Format View
EHoelThesis05-1980.pdf 945.2Kb PDF View/Open

This item appears in the following Collection(s)