Effect of Reynolds number on performance of a small centrifugal pump

Show full item record

Title: Effect of Reynolds number on performance of a small centrifugal pump
Author: Day, Steven; Lemire, P.; Flack, R.
Abstract: A study of a small centrifugal blood pump has been made to address the effectiveness of traditional pump affinity laws and the influence that viscous effects, as characterized by the Reynolds number, have on the pump performance. This was investigated both experimentally and numerically on models of a small implantable centrifugal blood pump, which has an impeller diameter of 46 mm with a log spiral volute. In the experiments, the Head-Flow curves were determined for speeds between 500 and 3000 rpm and for two different viscosity fluids. It was found that lower Reynolds number flows did not adhere to conventional pump affinity laws, whereas higher Reynolds number flows scale very effectively according to pump affinity laws. The numerical study consisted of comparing the generated head and internal flow field of the pump scaled based on traditional affinity laws with and without consideration of the Reynolds number. Like the experimental results, the numerical simulations indicate that consideration of the Reynolds number is necessary to insure accurate scaling in this small pump.
Description: Please see www.asme.org for more information.
Record URI: http://hdl.handle.net/1850/8596
Date: 2003-07

Files in this item

Files Size Format View
ASME_Copyright.pdf 187.6Kb PDF View/Open

The following license files are associated with this item:

This item appears in the following Collection(s)

Show full item record

Search RIT DML


Advanced Search

Browse