High accuracy imaging polarimetry with NICMOS

Show full item record

Title: High accuracy imaging polarimetry with NICMOS
Author: Batcheldor, D; Schneider, G; Hines, D. C.; Schmidt, G. D.; Axon, D. J.; Sparks, W.; Tadhunter, C.
Abstract: The ability of NICMOS to perform high accuracy polarimetry is currently hampered by an uncalibrated residual instrumental polarization at a level of 1.2 - 1.5%. To better quantify and characterize this residual we obtained observations of three polarimetric standard stars at three separate space-craft roll angles. Combined with archival data, these observations were used to characterize the residual instrumental polarization to enable NICMOS to reach its full polarimetric potential. Using these data, we calculate values of the parallel transmission coefficients that reproduce the ground-based results for the molarimetric standards. The uncertainties associated with the parallel transmission coefficients, a result of the photometric repeatability of the observations, dominate the accuracy of p and O. However the new coefficients now enable imaging polarimetry of targets with p = 1.0% at an accuracy of ±0.6% and ±15.
Record URI: http://hdl.handle.net/1850/9670
Date: 2009

Files in this item

Files Size Format View
Unavailable document.pdf 18.12Kb PDF View/Open

The following license files are associated with this item:

This item appears in the following Collection(s)

Show full item record

Search RIT DML


Advanced Search

Browse