Title: High-accuracy near-infrared imaging polarimetry with NICMOS
Author: Batcheldor, Daniel; Schneider, G.; Hines, D.C.; Schmidt, G.D.; Axon, D.J.; Robinson, A.; Sparks, W.; Tadhunter, C.
Abstract: The findings of a nine-orbit calibration plan carried out during HST Cycle 15, to fully determine the NICMOS camera 2 (2.0 !m) polarization calibration to high accuracy, are reported. Recently Ueta et al. and Batcheldor et al. have suggested that NICMOS possesses a residual instrumental polarization at a level of 1.2%–1.5%. This would completely inhibit the data reduction in a number of GO programs, and hamper the ability of the instrument to perform high-accuracy polarimetry. We obtained polarimetric calibration observations of three polarimetric standards at three spacecraft roll angles separated by ~60°. Combined with archival data, these observations were used to characterize the residual instrumental polarization in order for NICMOS to reach its full potential of accurate imaging polarimetry at p " 1%. Using these data, we place an 0.6% upper limit on the instrumental polarization and calculate values of the parallel transmission coefficients that reproduce the ground-based results for the polarimetric standards. The uncertainties associated with the parallel transmission coefficients, a result of the photometric repeatability of the observations, are seen to dominate the accuracy of p and ". However, the updated coefficients do allow imaging polarimetry of targets with p " 1:0% at an accuracy of +/-0.6% and +/-15°. This work enables a new caliber of science with HST.
Record URI: http://hdl.handle.net/1850/9918
Date: 2009-02

Files in this item

Files Size Format View
DBatcheldorArticle2-2009.pdf 329.5Kb PDF View/Open

The following license files are associated with this item:

This item appears in the following Collection(s)

Show full item record

Search RIT DML


Advanced Search

Browse